ISTIQ Noise Control Sdn Bhd
1, Jalan Utarid U5/17, Seksyen U5, Mahsing Integrated Industrial Park, 40150 Shah Alam, Selangor, Malaysia.
+603-7846 5288
Silencer
Blower Silencer
Blower Silencer
Blower Silencer for BahrainFor more information:
CALL US NOW for inquiry at +603-7846 5188 (Office) or 011-277 20340 (whatsapp) or email at noisecontrol.istiq@gmail.com
Arestor Pencucuh
Spark Arrestor @ Spark Arrester
ISTIQ SPARK ARRESTER remove sparks, soot and solid matter while preventing noise instead of muffling it. When exhaust gases enter the silencer, a special stationary impeller whirls the gases to throw out all solid matter, and at the same time, partially breaks up the exhaust slugs. Cleaning efficiency is high. Exhaust gases then enter the snubbing section in which the energy of the exhaust slug is further dissipated without interfering with the flow of low energy gases to the atmosphere. Model IXSA Provide Attenuation up to 30 dB.
Applications
ISTIQ SPARK ARRESTER are designed to efficiently reduce inlet and discharge noise of diesel engines, blowers, vacuum pumps, compressors and all situations requiring control of intake or outlet equipment noise.
Construction
Silencers are constructed from heavy gauge controlled cold quenched sheet steel with all welded construction. Internal components are stiffened and braced to minimise resonances and vibration induced fatigue. Flanges are supplied to Table C or American National Standard Institute (ANSI) requirement. Threaded pipe ends are to BSP or metric threads. Drain plugs are fitted as standard for removal of condensate. All external surfaces are finished with high
quality silicone based heat resistant aluminium paint which provides lasting protection at temperatures up to 600oC.
Selection Guidelines
When designing an exhaust system there are a number of factors that should be considered to maximize the design in terms of performance and cost. A few of the items that should be taken into consideration include:
- Acoustic Environment into which exhaust is discharging
- Engine Rating, i.e.
- Exhaust flow
- Allowable engine back pressure - Engine exhaust outlet noise level
- Engine Exhaust Outlet Design, i.e. single or dual outlets
- Exhaust Piping Arrangement within engine room
- Exhaust Piping Support, Anchoring, and Guiding
- Exhaust Stack Height
- Configuration of Exhaust Silencers, i.e. single or dual inlet
For more information:
CALL US NOW for inquiry at +603-7846 5188 (Office) or 011-277 20340 (whatsapp) or email at noisecontrol.istiq@gmail.com
Saluran Penyenyap
Duct Silencers / Attenuators
Application Notes
Whenever ventilation is required in the enclosed compartment and at the same time noise is to be controlled, installing duct silencers or attenuator are the best way to solve the problem. The silencers permit air to flow through while reduce the noise by absorbing it. In selecting a silencer, a balance between noise attenuations and pressure drop need to be considered carefully. By using internally developed software, ISTIQ NOISE CONTROL can help to make the right choice quickly and most importantly, accurately.Introduction
ISTIQ DUCT SILENCER are designed to efficiently reduce noise by generator sets, air handling systems, compressor, blower system and all situations requiring air intake and outlet for these equipments to operate.A duct silencer should always positioned in the plant room and if possible as close to the noise source as possible. Normally for a single equipment, two units of duct silencers - intake and discharge is required to effectively reduce the noise to a desired level.
Construction
ISTIQ DUCT SILENCER are available in two different models, which basically have two different thicknesses of splitters - 200 mm and 300 mm. The thicker the splitter the better performance at lower frequencies. Each of the models have six length sizes from 900 to 3000 mm. The cross sectional area has no limited size.ISTIQ DUCT SILENCER will be supplied in sections whenever the silencer dimension exceeded 2100W x 2100H x 2100mmL. This will make the transportation and installation easier. The assembly of sectionalized silencers to be done at site.
Applications
Some typical ISTIQ Duct Silencer applications and installations.
![]() ACOUSTIC TREATMENT ON COMPRESSORS |
![]() ACOUSTIC TREATMENT FOR VENTILATION SYSTEM |
For more information:
CALL US NOW for inquiry at +603-7846 5188 (Office) or 011-277 20340 (Whatsapp) or email at noisecontrol.istiq@gmail.com
Penyenyap Ekzos
Exhaust Silencer
ISTIQ EXHAUST SILENCER come in standard, stock silencers for general-purpose applications and custom models to fit most OEM engines. These include:
- MODEL IXP - Multi-Chamber Reactive Type Attenuation - 30 dB
- MODEL IXS - Straight Through Absorptive Type Attenuation - 20 dB
- MODEL IXC - Supercritical or Combination Attenuation - 35 dB
Applications
ISTIQ EXHAUST SILENCER are designed to efficiently reduce inlet and discharge noise of diesel engines, blowers, vacuum pumps, compressors and all situations requiring control of intake or outlet equipment noise.Construction
All silencers are constructed from heavy gauge hot rolled cold quenched sheet steel with all welded construction. Internal components are stiffened and braced to minimise resonances and vibration induced fatigue. Flanges are supplied to Table C or American National Standard Institute (ANSI) requirement. Threaded pipe ends are to BSP or metric threads. Drain plugs are fitted as standard for removal of condensate. All external surfaces are finished with high quality silicone based heat resistant aluminium paint which provides lasting protection at temperatures up to 600oC.Selection Guidelines
When designing an exhaust system there are a number of factors that should be considered to maximize the design in terms of performance and cost. A few of the items that should be taken into consideration include:- Acoustic Environment into which exhaust is discharging
- Engine Rating, i.e. - exhaust flow
- Allowable engine back pressure
- Engine exhaust outlet noise level
- Engine Exhaust Outlet Design, i.e. single or dual outlets
- Exhaust Piping Arrangement within engine room
- Exhaust Piping Support, Anchoring, and Guiding
- Exhaust Stack Height
- Configuration of Exhaust Silencers, i.e. single or dual inlet
CALL US NOW for inquiry at +603-7846 5188/+603-7846 5288 (Office) or 011-277 20340 (Whatsapp) or email at noisecontrol.istiq@gmail.com
Acoustic Louvers
Acoustic Louvers
Whenever space is the limiting factor in designing Acoustic Treatment system, ISTIQ ACOUSTIC LOUVERS are the best bet to solving the problem. Serving a dual functions - reducing the noise and at the same time performs as weather louvers, ISTIQ LOUVERS is easy to install.Aesthetically pleasing, they consist of fabricated metal louver blades with acoustic infill, alternated with air gaps and fitted into a four sided metal case.
Applications
Because of their excellent noise reduction capability, ISTIQ ACOUSTIC LOUVERS can be used in almost any situation which need to control the noise but at the same time must permit the flow of air. The modular design and wide range of sizes and finishes allows them to be used in most industrial or commercial projects. They are ideal for use in any of the following applications:- Plant room ventilation
- Air conditioning plants
- Power stations
- Cooling towers
- Diesel generator sets Canopy
- Refrigeration plants
- Pump Houses
- Ventilation exhaust plenum chambers
Features
ISTIQ ACOUSTIC LOUVERS come in two models - Model Lx and Model Ly. Each model offers of two different length, 300mm and 600mm. The maximum single unit available is 2400mm width and 2400mm in height. If a bigger size is required, it can be done through combination of modules.Construction
ISTIQ ACOUSTIC LOUVERS consist of fabricated metal blades with acoustic infill placed internally. The open area between each blade has been carefully designed to gain maximum acoustic performance and minimum airflow resistance. The casings are fabricated from galvanised iron or mild steel and have folded flanges both at the front and back. This design provides extra rigidity and the means for fixing the louvre blades in position. A bird guard, manufactured from 25mm square galvanized wire, can be supplied fitted to the rear face of all models, if required.
For more information:
CALL US NOW for inquiry at +603-7846 5188/+603-7846 5288 (Office) or 011-277 20340 (Whatsapp) or email at noisecontrol.istiq@gmail.com
Penyenyap Lubang Angin
Vent Silencer, Boiler Silencer
ISTIQ VENT SILENCER reduce the noise produced by the expansion of gas or steam from elevated pressures to atmospheric pressure. These absorptive silencers are used to suppress noise generated by high velocity gas streams such as steam vents, safety relief valve outlets, system blow downs and purge outlets. Each vent silencer is designed to attenuate the noise level to the required sound pressure level criteria at a given distance from the silencer.
Applications
steam boiler relief valves
- superheater header relief valves
- boiler startup and purge
- high-pressure air vents
- natural gas blowdowns
- switch valves
- compressor blowoffs
- autoclaves
- steam ejectors
Construction
Selection Guidelines
-
Type of gas
- Molecular weight or specific gravity
- Ratio of specific heats
- Flow rate (lb/hr, ACFM or SCFM)
- Pressure and temperature upstream of valve and silencer
- Maximum allowable pressure drop (PSI) for valve and silencer
- Manufacturer’s name, and valve type and size
- Unsilenced noise levels from valve (if available)
- Silenced noise level (required at desired distance from source)
- Silencer inlet size and pressure rating
- Inlet orientation, axial or side
- Silencer orientation, vertical or horizontal
- Piping arrangement, including schematic if available
- Other required options
For more information:
CALL US NOW for inquiry at +603-7846 5188/+603-7846 5288 (Office) or 011-277 20340 (Whatsapp) or email at noisecontrol.istiq@gmail.com